!7748 modify windows CI bat

Merge pull request !7748 from lyvette/windows
pull/7748/MERGE
mindspore-ci-bot 4 years ago committed by Gitee
commit fd7732cbcb

@ -1,128 +0,0 @@
@rem Copyright 2020 Huawei Technologies Co., Ltd
@rem
@rem Licensed under the Apache License, Version 2.0 (the "License");
@rem you may not use this file except in compliance with the License.
@rem You may obtain a copy of the License at
@rem
@rem http://www.apache.org/licenses/LICENSE-2.0
@rem
@rem Unless required by applicable law or agreed to in writing, software
@rem distributed under the License is distributed on an "AS IS" BASIS,
@rem WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
@rem See the License for the specific language governing permissions and
@rem limitations under the License.
@rem ============================================================================
@echo off
@title run_benchmark_nets
setlocal enabledelayedexpansion
SET BASEPATH=%CD%
SET OUTPUT_PATH=%BASEPATH%/output
SET TOOL_PATH=%1
SET TOOL_PATH=%TOOL_PATH:"=%/windows_x64
SET MODEL_PATH=%2
SET MODEL_PATH=%MODEL_PATH:"=%/models/hiai
SET BENCHMARK_BASE=%BASEPATH:"=%/output/benchmark
SET MODEL_CONFIG=%BASEPATH%/win_models.cfg
cd /d %BASEPATH%
IF EXIST "%BASEPATH%/output" (
rd /s /q output
)
md output
cd /d %OUTPUT_PATH%
IF EXIST benchmark (
rd /s /q benchmark
)
md benchmark
SET RET_CODE=0
cd benchmark
unzip "%TOOL_PATH%/mindspore-lite-*-converter-win-cpu.zip"
IF NOT %errorlevel% == 0 (
echo "Decompression of converter tool fail!"
SET RET_CODE=1
goto run_eof
)
unzip "%TOOL_PATH%/mindspore-lite-*-win-runtime-x86-cpu.zip"
IF NOT %errorlevel% == 0 (
echo "Decompression of runtime tool fail!"
SET RET_CODE=1
goto run_eof
)
md ms
SET TYPE_ID=''
SET MODEL_NAME=''
SET SUFFIX=''
echo "Convert models"
cd mindspore-lite-*-converter-win-cpu/converter
for /f "tokens=1-2 delims= " %%i in (%MODEL_CONFIG%) do (
for /f "tokens=1-2 delims=." %%k in ("%%j") do (
SET TYPE_ID=%%i
SET MODEL_NAME=%%k
SET SUFFIX=%%l
)
if !TYPE_ID!==1 (converter_lite --fmk=MINDIR --modelFile="%MODEL_PATH%/!MODEL_NAME!.!SUFFIX!" --outputFile="%BENCHMARK_BASE%/ms/!MODEL_NAME!.!SUFFIX!")
if !TYPE_ID!==2 (converter_lite --fmk=MINDIR --modelFile="%MODEL_PATH%/!MODEL_NAME!.!SUFFIX!" --outputFile="%BENCHMARK_BASE%/ms/!MODEL_NAME!.!SUFFIX!_train" --trainModel=true)
if !TYPE_ID!==3 (converter_lite --fmk=CAFFE --modelFile="%MODEL_PATH%/!MODEL_NAME!.prototxt" --weightFile="%MODEL_PATH%/!MODEL_NAME!.caffemodel" --outputFile="%BENCHMARK_BASE%/ms/!MODEL_NAME!")
if !TYPE_ID!==4 (converter_lite --fmk=ONNX --modelFile="%MODEL_PATH%/!MODEL_NAME!.!SUFFIX!" --outputFile="%BENCHMARK_BASE%/ms/!MODEL_NAME!.!SUFFIX!")
if !TYPE_ID!==5 (converter_lite --fmk=TFLITE --modelFile="%MODEL_PATH%/!MODEL_NAME!.!SUFFIX!" --outputFile="%BENCHMARK_BASE%/ms/!MODEL_NAME!.!SUFFIX!")
if !TYPE_ID!==6 (converter_lite --fmk=TFLITE --modelFile="%MODEL_PATH%/!MODEL_NAME!.!SUFFIX!" --outputFile="%BENCHMARK_BASE%/ms/!MODEL_NAME!.!SUFFIX!" --quantType=AwareTraining)
if !TYPE_ID!==7 (converter_lite --fmk=TFLITE --modelFile="%MODEL_PATH%/!MODEL_NAME!.!SUFFIX!" --outputFile="%BENCHMARK_BASE%/ms/!MODEL_NAME!.!SUFFIX!_posttraining" --quantType=PostTraining --configFile="%MODEL_PATH%/!MODEL_NAME!.!SUFFIX!_posttraining.config")
if !TYPE_ID!==8 (converter_lite --fmk=TFLITE --modelFile="%MODEL_PATH%/!MODEL_NAME!.!SUFFIX!" --outputFile="%BENCHMARK_BASE%/ms/!MODEL_NAME!.!SUFFIX!_weightquant" --quantType=WeightQuant --bitNum=8 --quantWeightSize=500 --quantWeightChannel=16)
IF !errorlevel! == 0 (
echo "Run converter for model (TYPE_ID=!TYPE_ID!) !MODEL_NAME!.!SUFFIX! : pass!"
) ELSE (
echo "Run converter for model (TYPE_ID=!TYPE_ID!) !MODEL_NAME!.!SUFFIX! : fail!"
SET RET_CODE=1
goto run_eof
)
)
echo "Run converted models"
cd /d %BENCHMARK_BASE%/mindspore-lite-*-win-runtime-x86-cpu/benchmark
SET INPUT_BASE=%MODEL_PATH%/input_output/input
SET OUTPUT_BASE=%MODEL_PATH%/input_output/output
for /f "tokens=1-2 delims= " %%i in (%MODEL_CONFIG%) do (
for /f "tokens=1-2 delims=." %%k in ("%%j") do (
SET TYPE_ID=%%i
SET MODEL_NAME=%%k
SET SUFFIX=%%l
)
if !TYPE_ID!==1 (benchmark --modelFile="%BENCHMARK_BASE%/ms/!MODEL_NAME!.!SUFFIX!.ms" --inDataFile="%INPUT_BASE%/!MODEL_NAME!.!SUFFIX!.ms.bin" --benchmarkDataFile="%OUTPUT_BASE%/!MODEL_NAME!.!SUFFIX!.ms.out" --accuracyThreshold=1.5)
if !TYPE_ID!==2 (benchmark --modelFile="%BENCHMARK_BASE%/ms/!MODEL_NAME!.!SUFFIX!_train.ms" --inDataFile="%INPUT_BASE%/!MODEL_NAME!.!SUFFIX!.ms.bin" --benchmarkDataFile="%OUTPUT_BASE%/!MODEL_NAME!.!SUFFIX!.ms.out" --accuracyThreshold=1.5)
if !TYPE_ID!==3 (benchmark --modelFile="%BENCHMARK_BASE%/ms/!MODEL_NAME!.ms" --inDataFile="%INPUT_BASE%/!MODEL_NAME!.ms.bin" --benchmarkDataFile="%OUTPUT_BASE%/!MODEL_NAME!.ms.out")
if !TYPE_ID!==4 (benchmark --modelFile="%BENCHMARK_BASE%/ms/!MODEL_NAME!.!SUFFIX!.ms" --inDataFile="%INPUT_BASE%/!MODEL_NAME!.!SUFFIX!.ms.bin" --benchmarkDataFile="%OUTPUT_BASE%/!MODEL_NAME!.!SUFFIX!.ms.out")
if !TYPE_ID!==5 (benchmark --modelFile="%BENCHMARK_BASE%/ms/!MODEL_NAME!.!SUFFIX!.ms" --inDataFile="%INPUT_BASE%/!MODEL_NAME!.!SUFFIX!.ms.bin" --benchmarkDataFile="%OUTPUT_BASE%/!MODEL_NAME!.!SUFFIX!.ms.out")
if !TYPE_ID!==6 (benchmark --modelFile="%BENCHMARK_BASE%/ms/!MODEL_NAME!.!SUFFIX!.ms" --inDataFile="%INPUT_BASE%/!MODEL_NAME!.!SUFFIX!.ms.bin" --benchmarkDataFile="%OUTPUT_BASE%/!MODEL_NAME!.!SUFFIX!.ms.out")
if !TYPE_ID!==7 (benchmark --modelFile="%BENCHMARK_BASE%/ms/!MODEL_NAME!.!SUFFIX!_posttraining.ms" --inDataFile="%MODEL_PATH%/../../quantTraining/mnist_calibration_data/00099.bin" --benchmarkDataFile="%OUTPUT_BASE%/!MODEL_NAME!.!SUFFIX!_posttraining.ms.out")
if !TYPE_ID!==8 (benchmark --modelFile="%BENCHMARK_BASE%/ms/!MODEL_NAME!.!SUFFIX!_weightquant.ms" --inDataFile="%INPUT_BASE%/!MODEL_NAME!.!SUFFIX!.ms.bin" --benchmarkDataFile="%OUTPUT_BASE%/!MODEL_NAME!.!SUFFIX!.ms.out")
IF !errorlevel! == 0 (
echo "Run benchmark for model (TYPE_ID=!TYPE_ID!) !MODEL_NAME!.!SUFFIX! : pass!"
) ELSE (
echo "Run benchmark for model (TYPE_ID=!TYPE_ID!) !MODEL_NAME!.!SUFFIX! : fail!"
SET RET_CODE=1
goto run_eof
)
)
:run_eof
IF %RET_CODE% == 0 (
SET errorlevel=0
echo "Run models in Windows success!"
) ELSE (
SET errorlevel=1
echo "Run models in Windows fail!"
)
cd /d %BASEPATH%

@ -17,8 +17,6 @@
5 mtk_AADB_HADB_MBV2_model_f16.tflite
5 ml_object_detect_1.tflite
5 lite-model_arbitrary-image-stylization-inceptionv3_fp16_predict_1.tflite
6 lite-model_aiy_vision_classifier_birds_V1_3.tflite
6 ssd_mobilenet_v1_1_default_1.tflite
6 object_detection_mobile_object_localizer_v1_1_default_1.tflite
7 mobilenet.tflite
8 ml_face_openclose.tflite
5 scan_hms_angle1.tflite
5 scan_hms_detect.tflite

@ -14,15 +14,115 @@
@rem ============================================================================
@echo off
@title win_run_test
setlocal enabledelayedexpansion
SET BASEPATH=%CD%
SET OUTPUT_PATH=%BASEPATH%/output
SET TOOL_PATH=%1
SET TOOL_PATH=%TOOL_PATH:"=%/windows_x64
SET MODEL_PATH_BASE=%2
SET MODEL_PATH=%MODEL_PATH_BASE:"=%/models/hiai
SET BENCHMARK_BASE=%BASEPATH:"=%/output/benchmark
SET MODEL_CONFIG=%BASEPATH%/win_models.cfg
call run_benchmark_nets.bat %1 %2
cd /d %BASEPATH%
IF EXIST "%BASEPATH%/output" (
rd /s /q output
)
md output
cd /d %OUTPUT_PATH%
IF EXIST benchmark (
rd /s /q benchmark
)
md benchmark
SET RET_CODE=0
7z x -r "%TOOL_PATH%/mindspore-lite-*-converter-win-cpu.zip" -o"%BENCHMARK_BASE%"
IF NOT %errorlevel% == 0 (
echo "benchmark fail!"
SET errorlevel=1
) ELSE (
echo "run benchmark tests success."
echo "Decompression of converter tool fail!"
SET RET_CODE=1
goto run_eof
)
7z x -r "%TOOL_PATH%/mindspore-lite-*-win-runtime-x86-cpu.zip" -o"%BENCHMARK_BASE%"
IF NOT %errorlevel% == 0 (
echo "Decompression of runtime tool fail!"
SET RET_CODE=1
goto run_eof
)
cd /d %BASEPATH%
cd benchmark
md ms
SET TYPE_ID=''
SET MODEL_NAME=''
SET SUFFIX=''
echo "Convert models"
cd mindspore-lite-*-converter-win-cpu/converter
for /f "tokens=1-2 delims= " %%i in (%MODEL_CONFIG%) do (
for /f "tokens=1-2 delims=." %%k in ("%%j") do (
SET TYPE_ID=%%i
SET MODEL_NAME=%%k
SET SUFFIX=%%l
)
if !TYPE_ID!==1 (converter_lite --fmk=MINDIR --modelFile="%MODEL_PATH%/!MODEL_NAME!.!SUFFIX!" --outputFile="%BENCHMARK_BASE%/ms/!MODEL_NAME!.!SUFFIX!")
if !TYPE_ID!==2 (converter_lite --fmk=MINDIR --modelFile="%MODEL_PATH%/!MODEL_NAME!.!SUFFIX!" --outputFile="%BENCHMARK_BASE%/ms/!MODEL_NAME!.!SUFFIX!_train" --trainModel=true)
if !TYPE_ID!==3 (converter_lite --fmk=CAFFE --modelFile="%MODEL_PATH%/!MODEL_NAME!.prototxt" --weightFile="%MODEL_PATH%/!MODEL_NAME!.caffemodel" --outputFile="%BENCHMARK_BASE%/ms/!MODEL_NAME!")
if !TYPE_ID!==4 (converter_lite --fmk=ONNX --modelFile="%MODEL_PATH%/!MODEL_NAME!.!SUFFIX!" --outputFile="%BENCHMARK_BASE%/ms/!MODEL_NAME!.!SUFFIX!")
if !TYPE_ID!==5 (converter_lite --fmk=TFLITE --modelFile="%MODEL_PATH%/!MODEL_NAME!.!SUFFIX!" --outputFile="%BENCHMARK_BASE%/ms/!MODEL_NAME!.!SUFFIX!")
if !TYPE_ID!==6 (converter_lite --fmk=TFLITE --modelFile="%MODEL_PATH%/!MODEL_NAME!.!SUFFIX!" --outputFile="%BENCHMARK_BASE%/ms/!MODEL_NAME!.!SUFFIX!" --quantType=AwareTraining)
if !TYPE_ID!==7 (converter_lite --fmk=TFLITE --modelFile="%MODEL_PATH%/!MODEL_NAME!.!SUFFIX!" --outputFile="%BENCHMARK_BASE%/ms/!MODEL_NAME!.!SUFFIX!_posttraining" --quantType=PostTraining --configFile="%MODEL_PATH%/!MODEL_NAME!.!SUFFIX!_posttraining.config")
if !TYPE_ID!==8 (converter_lite --fmk=TFLITE --modelFile="%MODEL_PATH%/!MODEL_NAME!.!SUFFIX!" --outputFile="%BENCHMARK_BASE%/ms/!MODEL_NAME!.!SUFFIX!_weightquant" --quantType=WeightQuant --bitNum=8 --quantWeightSize=500 --quantWeightChannel=16)
IF !errorlevel! == 0 (
echo "Run converter for model (TYPE_ID=!TYPE_ID!) !MODEL_NAME!.!SUFFIX! : pass!"
) ELSE (
echo "Run converter for model (TYPE_ID=!TYPE_ID!) !MODEL_NAME!.!SUFFIX! : fail!"
SET RET_CODE=1
goto run_eof
)
)
echo "Run converted models"
cd /d %BENCHMARK_BASE%/mindspore-lite-*-win-runtime-x86-cpu/benchmark
SET INPUT_BASE=%MODEL_PATH%/input_output/input
SET OUTPUT_BASE=%MODEL_PATH%/input_output/output
for /f "tokens=1-2 delims= " %%i in (%MODEL_CONFIG%) do (
for /f "tokens=1-2 delims=." %%k in ("%%j") do (
SET TYPE_ID=%%i
SET MODEL_NAME=%%k
SET SUFFIX=%%l
)
if !TYPE_ID!==1 (benchmark --modelFile="%BENCHMARK_BASE%/ms/!MODEL_NAME!.!SUFFIX!.ms" --inDataFile="%INPUT_BASE%/!MODEL_NAME!.!SUFFIX!.ms.bin" --benchmarkDataFile="%OUTPUT_BASE%/!MODEL_NAME!.!SUFFIX!.ms.out" --accuracyThreshold=1.5)
if !TYPE_ID!==2 (benchmark --modelFile="%BENCHMARK_BASE%/ms/!MODEL_NAME!.!SUFFIX!_train.ms" --inDataFile="%INPUT_BASE%/!MODEL_NAME!.!SUFFIX!.ms.bin" --benchmarkDataFile="%OUTPUT_BASE%/!MODEL_NAME!.!SUFFIX!.ms.out" --accuracyThreshold=1.5)
if !TYPE_ID!==3 (benchmark --modelFile="%BENCHMARK_BASE%/ms/!MODEL_NAME!.ms" --inDataFile="%INPUT_BASE%/!MODEL_NAME!.ms.bin" --benchmarkDataFile="%OUTPUT_BASE%/!MODEL_NAME!.ms.out")
if !TYPE_ID!==4 (benchmark --modelFile="%BENCHMARK_BASE%/ms/!MODEL_NAME!.!SUFFIX!.ms" --inDataFile="%INPUT_BASE%/!MODEL_NAME!.!SUFFIX!.ms.bin" --benchmarkDataFile="%OUTPUT_BASE%/!MODEL_NAME!.!SUFFIX!.ms.out")
if !TYPE_ID!==5 (benchmark --modelFile="%BENCHMARK_BASE%/ms/!MODEL_NAME!.!SUFFIX!.ms" --inDataFile="%INPUT_BASE%/!MODEL_NAME!.!SUFFIX!.ms.bin" --benchmarkDataFile="%OUTPUT_BASE%/!MODEL_NAME!.!SUFFIX!.ms.out")
if !TYPE_ID!==6 (benchmark --modelFile="%BENCHMARK_BASE%/ms/!MODEL_NAME!.!SUFFIX!.ms" --inDataFile="%INPUT_BASE%/!MODEL_NAME!.!SUFFIX!.ms.bin" --benchmarkDataFile="%OUTPUT_BASE%/!MODEL_NAME!.!SUFFIX!.ms.out")
if !TYPE_ID!==7 (benchmark --modelFile="%BENCHMARK_BASE%/ms/!MODEL_NAME!.!SUFFIX!_posttraining.ms" --inDataFile="%MODEL_PATH_BASE%/quantTraining/mnist_calibration_data/00099.bin" --benchmarkDataFile="%OUTPUT_BASE%/!MODEL_NAME!.!SUFFIX!_posttraining.ms.out")
if !TYPE_ID!==8 (benchmark --modelFile="%BENCHMARK_BASE%/ms/!MODEL_NAME!.!SUFFIX!_weightquant.ms" --inDataFile="%INPUT_BASE%/!MODEL_NAME!.!SUFFIX!.ms.bin" --benchmarkDataFile="%OUTPUT_BASE%/!MODEL_NAME!.!SUFFIX!.ms.out")
IF !errorlevel! == 0 (
echo "Run benchmark for model (TYPE_ID=!TYPE_ID!) !MODEL_NAME!.!SUFFIX! : pass!"
) ELSE (
echo "Run benchmark for model (TYPE_ID=!TYPE_ID!) !MODEL_NAME!.!SUFFIX! : fail!"
SET RET_CODE=1
goto run_eof
)
)
:run_eof
cd /d %BASEPATH%
IF %RET_CODE% == 0 (
SET errorlevel=0
echo "Run models in Windows success!"
) ELSE (
SET errorlevel=1
echo "Run models in Windows fail!"
)
exit /b %errorlevel%

Loading…
Cancel
Save